Features
Automatic synchronisation on multi-sounder system.
Continuously rated.
Stainless steel fixings.
Unit can be mounted using external lugs or internal BESA
compatible fixing positions.
Duplicate cable terminations (in & out for daisy-chain
installations).
Tropicalisation available on request.
Available with custom tone configurations and frequencies.
‘Programmable’ version available:
– 45 alarm tones
– 4 remotely selectable stages
– Any tone can be assigned to any stage
– User configurable continuous frequency tone
Approvals
VdS approved: EN54-3 (CPD 89/106/EEC).
UL & cULs approved: General signalling use.
GOST-R approved. Cert: POCC GB.JB05.H00144.
Marine Equipment Directive (MED)Certificate: 19 702 – 11 HH
Specification
Maximum output: 119dB(A) @ 1 metre [110dB(A) @ 10ft/3m]
Nominal output: 112dB(A) @ 1m +/- 3dB – Tone 2 [103dB(A) @
10ft/3m]
No. of tones: 45 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 112dB(A);
Min. 100dB(A) – Tone 2
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24V dc (10-30V dc);
48V dc (35-60V dc);
110V dc (90-250V dc)
[24V dc units can use 24V ac for single stage apps.]
Voltages AC: 24V ac; 115V ac; 230V ac
Stage switching: Negative or optional positive
Reverse polarity stage switching on DC units.
Ingress protection: IP66
Housing material: High impact UL94 V0 & 5VA FR ABS
Colour: Red (RAL3000)
Cable entries: 2 x M20 clearance gland entries in side & back
Terminals: 0.5 to 4.0mm²cables.
Operating temp: -25 to +55°C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 1.80kg/3.96Ibs AC:2.10kg/4.62Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.
Part Codes
Version: Part c ode:
24V dc A112NDC24[x]
48V dc A112NDC48[x]
110/230V dc A112NDC110[x]
24V ac A112NAC24[x]
115V ac A112NAC115[x]
230V ac A112NAC230[x]
[x] = Housing
colour:
R: Red
Suffix part number with ‘-P’ for programmable, 4 stage, 45 tone version (not available
with UL approval).
Suffix part number with ‘-UL’ for UL approved version
[110/230V dc unit not available as ULapproved]
Suffix part number with ‘-M’ for MED approved version.
[24V dc unit only]
Alarm Sounder
Version: Voltage: Current:
24V dc 10-30V dc 200mA*
48V dc 35-60V dc 120mA*
110/230V dc 90-250V dc 60mA
24V ac 50/60Hz +/-10% 500mA
115V ac 50/60Hz +/-10% 100mA
230V ac 50/60Hz +/-10% 60mA
* current at nominal voltage on Tone